Shop STERIS Online Account
- Products
- Sterile Processing
PRODUCTSSOFTWAREREPAIR SERVICESONSITE SPD SOLUTIONSOFFSITE SPD SERVICESCERTIFIED PRE-OWNEDDESIGN AND CONSTRUCTIONSTAFFINGSURGERY CENTERS
- Operating Room
PRODUCTSOR INTEGRATIONOR ENVIRONMENTREPAIR SERVICESCERTIFIED PRE-OWNEDDESIGN AND CONSTRUCTIONSTAFFINGSURGERY CENTERS
- Endoscopy Suite
ENDOSCOPE REPROCESSINGENDOSCOPY DEVICES AND ACCESSORIESENDOSCOPY EQUIPMENTSOFTWARE & AUDIOVISUAL TECHNOLOGYREPAIR SERVICESDESIGN AND CONSTRUCTIONSTAFFINGSURGERY CENTERS
- Education
- STERIS University
- Knowledge Center
- Service Training Center
- Resources
- Knowledge Center
- Safety Data Sheets
- Certificates of Analysis
- Instructions For Use
- Device Compatibility Matrix
- Medivators Hookup Guide
- Contact Us
- Contact Information
- Contact Form
- Get a Quote or Information
- Key Locations
- Locate Your STERIS Representatives
- Healthcare Live Chat
- Social Media Rules of Engagement
- Global Sites
Select Your Region
- United States
- Canada (EN)
- Canada (FR)
- United Kingdom
- Europe, Middle East and Africa
- Australia
- Asia-Pacific
- Brasil
- México
- América Latina
- United States
- Shop STERIS Online Account - UNITED STATES
- Shop STERIS Online Account - CANADA
- Shop STERIS Online Account - UNITED KINGDOM
- Shop STERIS Online Account - IRELAND
- Live Chat
- Email Alerts
- Capacity - Process up to 50lbs in 28 minutes, or 11lbs in as quick as 16 minutes
- Features - The most throughput of any low temperature sterilizer
- Compatibility - Compatible with the widest range of medical devices and materials, including 3D-printed materials
Browse Replacement Parts
Product Overview
Delivering unparalleled productivity for day-to-day Operating Room needs, the V-PRO maX 2 Low Temperature Sterilization System is designed for use in the terminal sterilization of medical devices. STERIS’s V-PRO maX 2 Sterilizer features the Fast Non Lumen cycle, allowing you to sterilize devices like cameras, telescopes, batteries, and laryngoscope blades in just 16 minutes.
How V-PRO maX 2 Low Temperature Sterilization System Works
This Low Temperature Sterilization System using proprietary Sterilant is intended for use in the terminal Sterilization of properly prepared (cleaned, rinsed, and dried, refer to Cleaning, Rinsing, and Drying in the Operator's Manual) medical devices in Healthcare Facilities. The preprogrammed Sterilization Cycles operate at low pressure and temperature, suitable for processing medical devices without leaving toxic residues.
The V-PRO maX 2 Sterilizer offers five cycles to efficiently sterilize the widest range of surgical instruments and medical devices using our proprietary vaporized hydrogen peroxide technology:
Cycle | Lumen† | Non Lumen | Flexible† | Fast Non Lumen | 3D Specialty Cycles |
---|---|---|---|---|---|
†Refer the operator manual for lumen size limitations. *da Vinci is a registered trademark of Intuitive Surgical, Inc. | |||||
Cycle Time | 52 Minutes | 28 Minutes | 35 Minutes | 16 Minutes | Varies |
Load Weight | 19.65 lb/8.9 kg | 50 lb/22.7 kg | 2 Scopes | 24 lb/11 kg: 1 scope and Non Lumened and Short Lumened Devices | 11 lb/5 kg, Non Lumened Devices Peel Pouch Only | For Cycle Details, Please Click Here |
Device Examples |
|
|
|
|
|
The innovative Moisture Check is included in every cycle to help confirm loads are dry and prevent cycle aborts. The Fast Non Lumen Cycle, only available with the V-PRO maX 2 Sterilizer, uses half the sterilant compared to all other V-PRO Sterilizer cycles.
Why V-PRO maX 2 Low Temperature Sterilization System?
- maX Compatibility – Setting the standard of processing the widest range of medical devices and materials. Including 3D printed devices
- maX Throughput – Process 11 lbs. (5 Kg.) of non lumened devices in 16 minutes, or process 50 lbs. of non lumened devices in 28 minutes
- maX Ease – Simple, intuitive cycle selection via large icons makes training and day-to-day use easy. Hands-free chamber access with an integrated foot pedal makes loading quick and easy
- maX Simplicity – A line of dedicated consumables, including sterilant, biological indicators, chemical indicators, and tape, to enable packaging and processing steps
- maX Savings – VAPROX HC Sterilant Smart Cup technology notifies you of remaining sterilant and cup expiration to help reduce waste
Supporting Your Sustainability Goals
- Conserve Utilities – Sterilize devices with no water consumption or wastewater produced using significantly less electricity than steam sterilization - only 2.3 kWh/cycle. Sterilizer does not generate notable heat that can impact the HVAC load
Learn more about STERIS' commitment to Sustainability
Specifications
- Overall Sterilizer Dimensions: can be installed recessed or with a cabinet package
- Cabinet (DD): 33 x 72 x 40-15/16" (838 x 1829 x 1040 mm)
- Recessed/Cabinet (SD): 33 x 72 x 38-5/16" (838 x 1829 x 973 mm)
- Chamber Size is 17 x 15 x 32-1/2" (432 x 381 x 826 mm) with 4.8 cubic feet (136 L) of volume
- Utility Requirements - no plumbing, special ventilation, or air supply. Only a standard 20amp dedicated wall outlet is needed
Device Compatibility
Confirm that your medical devices and accessories are compatible for processing with our Low Temperature Systems.
SEARCH FOR MY DEVICES
Commonly Searched Devices Validated for Use in V-PRO Sterilizers
Olympus®
Device Type | Model |
---|---|
Bronchoscopes | BF, such as BF1T60 |
Cystoscopes | CYF, such as CYF V2 |
Pleuroscope | LTF, such as LTF VH1 |
Karl Storz®
Device Type | Model |
---|---|
Ureteroscope | 11278AU1 |
Rhino Pharyngoscope | 11101RP2 |
C-Mac Intubation Fiberscope | 11302BD2 |
Fiberscope |
Intuitive Surgical®
Device Type | Model |
---|---|
Endoscopes | For Xi and Si Robot |
Stryker
Device Type | Model |
HD Cameras | 1488-010-000 |
Cardinal Health™
Device Type | Model |
---|---|
Sterilization Wraps | Various |
Medline®
Device Type | Model |
---|---|
Sterilization Wraps | Various |
Halyard Health®
Device Type | Model |
---|---|
Sterilization Wraps | Various |
Visit the V-PRO Device Matrix to find out if your device can be reprocessed in a V-PRO Low Temperature Sterilization System. The Device Matrix contains information on devices from hundreds of manufacturers including:
- Aesculap
- Arthrex
- BK Ultrasound
- Brainlab
- Braun
- Cardinal Health
- Fisher & Paykel
- GE Healthcare
- Halyard Health
- Hitachi Aloka
- Intuitive Surgical
- Karl Storz
- Medline
- Medovations
- Mizuho
- Olympus
- Philips
- Richard Wolf
- St. Jude Medical
- Stryker
- Teleflex
- Truphatek
- Volk
- WelchAllyn
SEARCH FOR MY DEVICES
Connectivity and Electronic Record Management with ConnectAssure™ Technology
Seamlessly connect and get immediate results from your V-PRO maX 2 Low Temperature Sterilizer and Celerity Incubator with ConnectAssure Technology. ConnectAssure Technology Data Export software helps promote compliance throughout the facility by interfacing compatible STERIS products with SPM Surgical Asset Tracking Softwareand many of the other leading instrument tracking systems.
FAQs
What can the V-PRO maX 2 Low Temperature Sterilizer sterilize?
The V-PRO maX 2 Low Temperature Sterilizer can sterilize more than just instruments that are heat sensitive. Devices like batteries, rigid endoscopes, general stainless steel instruments, bronchoscopes, and others will benefit from short cycle times with a gentle, low temperature process.
How fast can the V-PRO maX 2 Low Temperature Sterilizer sterilize?
The V-PRO maX 2 Low Temperature Sterilizer has four cycles that range from very fast to extremely fast, with all cycles starting with a moisture checking condition phase included in the total time:
- The Lumen Cycle will process rigid lumened devices in around 52 minutes
- The Flexible Cycle will process flexible scopes in around 35 minutes
- The Non Lumen Cycle will process general stainless steel and non lumened devices, including da Vinci endoscopes, in around 28 minutes
For the fastest turn-around, the Fast Non Lumen Cycle will process general stainless steel and non lumened instruments in pouches or pouched trays in around 16 minutes.
What STERIS accessories are designed to work with the V-PRO maX 2 Low Temperature Sterilizer?
- Celerity™ HP Biological Indicators
- Celerity™ HP Challenge Packs
- Celerity™ HP Multivariable Chemical Indicator
- VAPROX™ HC Sterilant with RFID label
- Verdoc™ Vaporized VH2O2 Record Card with Process
- PRO-LITE Sterilization Trays, Instrument Organizers, and Silicone Mats
- Vis-U-All™ Low Temperature Sterilization Pouches and Tubing
What is the difference between STERIS’s V-PRO Low Temperature Sterilization Systems?
Explore the differences between V-PRO Sterilizers and other common VH2O2 Sterilizers based on important factors like chamber size, cycle time, utilities, electronic record-keeping capabilities, and more using our interactive tool.
Planning and Design
View, download, and print technical information for V-PRO maX 2, including CAD Blocks, Revit Family Objects, equipment drawings, technical data sheets, and more on the STERIS Architect Portal.
ACCESS DESIGN RESOURCES
Literature
OPERATORS MANUAL | |
---|---|
Document # | Document Title |
10085896 | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM |
10085896 | AMSCO V-PRO MAX 2 OPERATOR MANUAL - NORTH AMERICA |
10085897SR | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (SR) [NOT RWS] |
10085897TR | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (TR) [NOT RWS] |
10085898 | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) |
10085899 | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) |
10085900 | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) |
10085901 | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) |
10085903 | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (RU) |
10085905 | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (FI) |
10085906 | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) |
10085908 | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (NL) |
10085911 | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) |
10085915 | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (LT) |
11002050 | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (SV) |
11002051 | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (SK) |
11002052 | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) |
11002053 | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (LV) |
11002055 | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (CZ) |
TECH DATA SHEET | |
---|---|
Document # | Document Title |
10261907 | V-PRO MAX 2 |
10261907 DE (SD1047DE) | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT |
10261907 ES (SD1047ES) | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT |
10261907 FI (SD1047FI) | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT |
10261907 FR (SD1047FR) | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT |
10261907 IT (SD1047IT) | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT |
10261907 NL (SD1047NL) | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT |
10261907 PL (SD1047PL) | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT |
10261907 PTBR (SD1047PTBR) | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT |
10261907HU (SD1047HU) | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT |
PS00000469 | V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (AUSTRALIA) |
TECHNICAL MONOGRAPH | |
---|---|
Document # | Document Title |
10382631 | TECHNICAL DATA MONOGRAPH - V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM |
12873535 | TECHNICAL DATA MONOGRAPH - V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM |
14670162 | TECHNICAL DATA MONOGRAPH - V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (SPANISH) |
14670163 | TECHNICAL DATA MONOGRAPH - V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (ITALIAN) |
14670164 | TECHNICAL DATA MONOGRAPH - V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (PORTUGUESE) |
14670165 | TECHNICAL DATA MONOGRAPH - V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (GERMAN) |
LABORATORY REPORTS | |
---|---|
Document # | Document Title |
450-300-5505 | VALIDATION OF DOUBLE POUCH MICROBIAL EFFICACY IN V-PRO AND STERRAD STERILIZERS |
450-300-5505FR | VALIDATION OF DOUBLE POUCH MICROBIAL EFFICACY IN V-PRO AND STERRAD STERILIZERS |
WALL CHARTS | |
---|---|
Document # | Document Title |
M10421EN | PACK MONITORING WALL CHART |
M10471EN | V-PRO MAX2 CYCLE WEIGHT GUIDE |
M13023EN | V-PRO MAX 2 3D MATERIALS WALL CHART |
M3927EN | OPERATING AND INTERPRETING RESULTS FOR V-PRO MAX AND V-PRO MAX 2 STERILIZERS |
M3927EN-CA | OPERATING AND INTERPRETING RESULTS FOR V-PRO MAX AND V-PRO MAX 2 STERILIZERS |
M3927FR | OPERATING AND INTERPRETING RESULTS FOR V-PRO MAX AND V-PRO MAX 2 STERILIZERS |
M9600EN | MAX 2 AND 100NX QUICK REFERENCE GUIDE |
M9600EN-CA | MAX 2 AND 100NX QUICK REFERENCE GUIDE (CANADA) |
M9600FR | MAX 2 AND 100NX QUICK REFERENCE GUIDE (FRENCH) |
M9656EN | V-PRO MAX AND MAX 2 ROUTINE CHECKLIST FOR STERILIZER MAINTENANCE |
BROCHURE | |
---|---|
Document # | Document Title |
M10425EN | V-PRO CONSUMABLES BROCHURE |
M12994EN | V-PRO MAX 2 3D BROCHURE |
M9273EN | V-PRO MAX 2 BROCHURE (ENGLISH) |
M9273EN-CA | V-PRO MAX 2 BROCHURE |
M9273FR | V-PRO MAX 2 BROCHURE |
SELL SHEET | |
---|---|
Document # | Document Title |
M11331EN | INFOGRAPHIC- V-PRO BEATS STERRAD WITH A 1-2 PUNCH |
M4067EN | V-PRO COMPARISON MATRIX - MAX 2, 60, STERRAD 100NX, STERRAD 100S AND STERRAD NX |
M9278EN | V-PRO TRAYS SELL SHEET |
SAMPLE PROCEDURES | |
---|---|
Document # | Document Title |
M9475EN | QUALIFICATION TESTING OF V-PRO STERILIZERS FOLLOWING INSTALLATION OR MAJOR REPAIR |
Related Products
View Product
View Product
View Product
View Product